PROLASTIC® 55Z
- Flexible, polymer-modified thick coating for building waterproofing
- indoors and outdoors
- vertical and horizontal
Pictograms

APPLICATION LOCATION
outside: floor, wall
inside: Floor, wall

PROCESSING TEMPERATURE
(air, surroundings, product)
min. + 5°C to max. + 25°C

PERSONAL PROTECTIVE EQUIPMENT:
Safety goggles und
gloves

MIXING:
Component ratio: a 1 : b 1 kg

APPROACH:
DLX-stirrer
2 minutes

PROCESSING TIME:
30 minutes

TOOLS / ACCESSORIES:
Smoother

CLEANING THE TOOLS
Water

STORAGE
Duration: 12 months
Conditions: dry, frost-free

DISPOSEL COMPANY
Interseroh Transportverpackung
20447

Once the packaging material has been emptied completely, it can be sent to an Interseroh point for recycling.
Features
Properties
PROLASTIC® 55Z is a 2-component, bitumen-free thick coating for the highest demands. Easy, fast, flexible at low temperatures, highly crack-bridging (RÜ3-E) and universally applicable. Particularly suitable for the surface sealing of basements and plinths that are under time pressure.- highly crack-bridging
- flexible at low temperatures
- UV-resistant
- extremely pressure-resistant
- frost and de-icing salt-resistant
- suitable for filling, brushing and spraying
- very low emission
- solvent-free
- bitumen-free
- can be plastered over
- paintable
Applications
- Waterproofing of building components in contact with the ground in accordance with DIN 18533
- Renovation of old bitumen waterproofing
- Base sealing
- Sealing the wall-sole connection
- Strip sealing of structural joints
- Sealing of level thresholds, doors and window elements
- Base point sealing of the facing brick shell
- Floor slab waterproofing
- Horizontal sealing under wall contact surfaces
- Component sealing under tiles and slabs
- Bonding of insulation boards
- Sealing of tanks and basins in accordance with DIN 18535
- Carbonation brake on concrete (to protect the foundation)
- WTA internal waterproofing
Composition
- Liquid component: polymer dispersion, additives
- Powder: special cements, mineral aggregates, additives, pigments
Processing
Substrate
Suitable substrates
- Masonry in accordance with DIN EN 1996, e.g. made of bricks, hollow blocks and solid blocks made of lightweight concrete and concrete, slag bricks, sand-lime bricks, aerated concrete blocks, concrete shuttering blocks, mixed masonry
- Concrete / reinforced concrete in accordance with EN 206-1 in conjunction with DIN 1045-2
- Plasters of category CS III or CS IV according to DIN EN 998-1
- Existing bitumen-based paints and coatings
- Cement screeds
- Old, firmly adhering tile coverings
Properties/tests
- The substrate must be frost-free, surface-dry, load-bearing, clean and free from contamination and separating layers of any kind (e.g. paint coats, formwork oils).
- The surface of the substrate must be dry.
- Plasters must be hardened.
- Concrete must be at least 3 months old in accordance with DIN 18535 – Sealing of tanks and basins in solid construction.
- Substrates containing tar are not suitable and must be completely removed.
Substrate
Vorbereitung
- Sintered layers or stubborn dirt must be removed mechanically (diamond grinding).
- On the surfaces to be sealed, external corners must be chamfered and internal corners must be provided with a sealing fillet or sealing tape (in accordance with the regulations).
- For masonry according to DIN 1053, butt joints wider than 5 mm must be sealed with mortar on the outside, e.g. for bricks that are not laid “crisply".
- Depressions larger than 5 mm, such as mortar pockets or break-outs, must be filled in advance with INTRASIT ® SM 54Z / INTRASIT® RZ1 55HSP.
- Special measures are required to close the pores in masonry made of lightweight or concrete blocks with porous structure (e.g. scratch coat with PROLASTIC® 55Z). The filler must be dried/set for approx. 2 hours before the next work step.
- Concrete needs to be checked as well. Existing defects and formwork ridges must be removed in the same way as for masonry.
- Pores, open or concealed, can lead to blistering in the fresh coating, e.g. when exposed to sunlight. To minimize the risk of blistering, a scratch coat of PROLASTIC® 55Z should be applied. The filler must be allowed to dry/set for approx. 2 hours before the next work step.
- Before applying PROLASTIC® 55Z, the surface to be sealed must be thoroughly cleaned (e.g. by vacuuming) and primed with IMBERAL Aquarol 10D.
- Clean existing bitumen-based paints and coatings (e.g. with a high-pressure cleaner) and apply a scratch coat of PROLASTIC® 55Z after drying.
- EPS and XPS panels must first be treated with a suitable reinforcement mortar and mesh in the plinth area.
- In transition areas between the structure and installation elements such as windows or doors, these must be roughly sanded and then HADALAN HV Uni 30DD is applied.
Technical data
| Processing temperature | +5°C to + 25°C |
| workable time | approx. 30 minutes |
| Load-bearing capacity | after approx. 24 hours |
| Revisability | after approx. 3 hours |
Article
| Article No. | Article Abbreviation | GTIN/EAN 4004637 | Package size |
|---|---|---|---|
| 40539 | PROLASTIC 55Z 2-comp. grey | - 40539 5 | 26 kg/combination container |
Downloads
| Technical data sheet PROLASTIC 55Z | download | |
| Safety data sheet PROLASTIC 55Z | download | |
| Environmental Product Declaration (EPD) for modified mineral mortars – Group 3 | download | |
| Sustainability data sheet PROLASTIC 55Z | download | |
| Execution protocol FPD | download | |
| Special agreement DIN 18533 PROLASTIC 55Z | download | |
| Brochure PROLASTIC 55Z | download | |
| EMICODE Licence PROLASTIC 55Z | download | |
| abP Flexible Polymer-modified thick coating (FPD) – PROLASTIC 55Z | download | |
| abP Mineral-Based Sealing Slurry (MDS) – PROLASTIC 55Z | download | |
| WTA-Certificate PROLASTIC 55Z WTA-Interior sealing | download | |
| Test certificate PROLASTIC 55Z according to DIN EN 15814 (PMBC) | download | |
| Test report PROLASTIC 55Z Test with negative water pressure | download | |
| Test report on radon protection PROLASTIC 55Z | download |