<span class="black">PROLASTIC®</span> 55Z

PROLASTIC® 55Z

  • Flexible, polymer-modified thick coating for building waterproofing
  • indoors and outdoors
  • vertical and horizontal

Pictograms

APPLICATION LOCATION
outside: floor, wall
inside: Floor, wall

PROCESSING TEMPERATURE
(air, surroundings, product)
min. + 5°C to max. + 25°C

PERSONAL PROTECTIVE EQUIPMENT:
Safety goggles und
gloves

MIXING:
Component ratio: a 1 : b 1 kg

APPROACH:
DLX-stirrer
2 minutes

PROCESSING TIME:
30 minutes

TOOLS / ACCESSORIES:
Smoother

CLEANING THE TOOLS
Water

STORAGE
Duration: 12 months
Conditions: dry, frost-free

DISPOSEL COMPANY
Interseroh Transportverpackung
20447

Once the packaging material has been emptied completely, it can be sent to an Interseroh point for recycling.

Features

Properties

PROLASTIC® 55Z is a 2-component, bitumen-free thick coating for the highest demands. Easy, fast, flexible at low temperatures, highly crack-bridging (RÜ3-E) and universally applicable. Particularly suitable for the surface sealing of basements and plinths that are under time pressure.

  • highly crack-bridging
  • flexible at low temperatures
  • UV-resistant
  • extremely pressure-resistant
  • frost and de-icing salt-resistant
  • suitable for filling, brushing and spraying
  • very low emission
  • solvent-free
  • bitumen-free
  • can be plastered over
  • paintable

Applications

  • Waterproofing of building components in contact with the ground in accordance with DIN 18533
  • Renovation of old bitumen waterproofing
  • Base sealing
  • Sealing the wall-sole connection
  • Strip sealing of structural joints
  • Sealing of level thresholds, doors and window elements
  • Base point sealing of the facing brick shell
  • Floor slab waterproofing
  • Horizontal sealing under wall contact surfaces
  • Component sealing under tiles and slabs
  • Bonding of insulation boards
  • Sealing of tanks and basins in accordance with DIN 18535
  • Carbonation brake on concrete (to protect the foundation)
  • WTA internal waterproofing

Composition

  • Liquid component: polymer dispersion, additives
  • Powder: special cements, mineral aggregates, additives, pigments

Processing

Substrate

Suitable substrates

  • Masonry in accordance with DIN EN 1996, e.g. made of bricks, hollow blocks and solid blocks made of lightweight concrete and concrete, slag bricks, sand-lime bricks, aerated concrete blocks, concrete shuttering blocks, mixed masonry
  • Concrete / reinforced concrete in accordance with EN 206-1 in conjunction with DIN 1045-2
  • Plasters of category CS III or CS IV according to DIN EN 998-1
  • Existing bitumen-based paints and coatings
  • Cement screeds
  • Old, firmly adhering tile coverings

Properties/tests

  • The substrate must be frost-free, surface-dry, load-bearing, clean and free from contamination and separating layers of any kind (e.g. paint coats, formwork oils).
  • The surface of the substrate must be dry.
  • Plasters must be hardened.
  • Concrete must be at least 3 months old in accordance with DIN 18535 – Sealing of tanks and basins in solid construction.
  • Substrates containing tar are not suitable and must be completely removed.

Substrate

Vorbereitung

  • Sintered layers or stubborn dirt must be removed mechanically (diamond grinding).
  • On the surfaces to be sealed, external corners must be chamfered and internal corners must be provided with a sealing fillet or sealing tape (in accordance with the regulations).
  • For masonry according to DIN 1053, butt joints wider than 5 mm must be sealed with mortar on the outside, e.g. for bricks that are not laid “crisply".
  • Depressions larger than 5 mm, such as mortar pockets or break-outs, must be filled in advance with INTRASIT ® SM 54Z / INTRASIT® RZ1 55HSP.
  • Special measures are required to close the pores in masonry made of lightweight or concrete blocks with porous structure (e.g. scratch coat with PROLASTIC® 55Z). The filler must be dried/set for approx. 2 hours before the next work step.
  • Concrete needs to be checked as well. Existing defects and formwork ridges must be removed in the same way as for masonry.
  • Pores, open or concealed, can lead to blistering in the fresh coating, e.g. when exposed to sunlight. To minimize the risk of blistering, a scratch coat of PROLASTIC® 55Z should be applied. The filler must be allowed to dry/set for approx. 2 hours before the next work step.
  • Before applying PROLASTIC® 55Z, the surface to be sealed must be thoroughly cleaned (e.g. by vacuuming) and primed with IMBERAL Aquarol 10D.
  • Clean existing bitumen-based paints and coatings (e.g. with a high-pressure cleaner) and apply a scratch coat of PROLASTIC® 55Z after drying.
  • EPS and XPS panels must first be treated with a suitable reinforcement mortar and mesh in the plinth area.
  • In transition areas between the structure and installation elements such as windows or doors, these must be roughly sanded and then HADALAN HV Uni 30DD is applied.

Technical data

Processing temperature +5°C to + 25°C
workable time approx. 30 minutes
Load-bearing capacity after approx. 24 hours
Revisability after approx. 3 hours

Article

Article No.Article AbbreviationGTIN/EAN 4004637Package size
40539PROLASTIC 55Z 2-comp. grey- 40539 526 kg/combination container

Downloads

Technical data sheet PROLASTIC 55Z
PDFdownload
Safety data sheet PROLASTIC 55Z
PDFdownload
Environmental Product Declaration (EPD) for modified mineral mortars – Group 3
PDFdownload
Sustainability data sheet PROLASTIC 55Z
PDFdownload
Execution protocol FPD
PDFdownload
Special agreement DIN 18533 PROLASTIC 55Z
PDFdownload
Brochure PROLASTIC 55Z
PDFdownload
EMICODE Licence PROLASTIC 55Z
PDFdownload
abP Flexible Polymer-modified thick coating (FPD) – PROLASTIC 55Z
PDFdownload
abP Mineral-Based Sealing Slurry (MDS) – PROLASTIC 55Z
PDFdownload
WTA-Certificate PROLASTIC 55Z WTA-Interior sealing
PDFdownload
Test certificate PROLASTIC 55Z according to DIN EN 15814 (PMBC)
PDFdownload
Test report PROLASTIC 55Z Test with negative water pressure
PDFdownload
Test report on radon protection PROLASTIC 55Z
PDFdownload