INTRASIT® MEK 18OS
- Micro-emulsion concentrate for subsequent horizontal waterproofing
- for creating horizontal barriers by pressureless injection using the borehole method and pressure injection using the low-pressure method (< 10 bar)
- for masonry with a high degree of moisture penetration
- solvent-free
- hydrophobic
Pictograms

APPLICATION LOCATION:
Inside
wall

PROCESSING TEMPERATURE
(air, surroundings, product)
min. 5°C to max. 35°C

PERSONAL PROTECTIVE EQUIPMENT:
Safety goggles und
gloves

MIXING:
Water addition: 1000 %

TOOLS / ACCESSORIES:
Injection packer

CLEANING THE TOOLS
Water

STORAGE
Duration: 12 months
Conditions: frost-free

DISPOSEL COMPANY
Interseroh Transportverpackung
20447
Features
Properties
INTRASIT® MEK 18OS is a hydrophobic horizontal barrier against capillary rising damp.- solvent-free
- hydrophobic
- concentrate
- good penetration
- for moisture penetration rates of up to 95 %
Applications
- cavity-free masonry
- Horizontal barriers
- non-pressurized injections using the borehole method
- Pressure injections using the low-pressure method < 10 bar
Composition
- Silicone resin emulsion
Processing
Substrate
Properties/tests
- The substrate must be firm, load-bearing and free of frost and cavities.
Processing
Processing
- Laying a horizontal barrier using the drill hole method:
Drill holes: Borehole diameter 18 mm; inclination 25°; height offset 10 cm; borehole spacing 12 cm
The boreholes can be drilled in one or two rows, depending on the condition of the masonry and the degree of moisture penetration. For saturation moisture levels above 75 %, the horizontal barrier must be installed in two rows. If possible, cross a bed joint. - Blow out drill holes.
- Fill larger cavities with INTRASIT BLS 54TR and re-drill after 1 to 2 days.
- Dilute INTRASIT MEK 18OS with water at a ratio of 1 : 10 for high moisture penetration and up to 1 : 14 for low moisture penetration.
- Impregnation is carried out alternately fresh in fresh. For unpressurized injection, allow at least 8 hours impregnation time. Use a borehole barrier reservoir.
- Alternatively, the material can be injected under low pressure (up to a maximum of 10 bar).
Cleaning the tools
- Clean tools immediately after use with water.
Notes
- Observe WTA data sheets, in particular WTA data sheet 4-10 "Injection procedure with certified injection materials against capillary moisture transport".
- Only mix as much emulsion as will be processed in one working day.
- Document material consumption.
- Please refer to the brochure "INTRASIT retrofit interior basement wall renovation".
Technical data
| Processing temperature | +5°C up to +35°C |
Article
| Article No. | Article Abbreviation | Color tone | GTIN/EAN 4004637 | Package size |
|---|---|---|---|---|
| 40118 | MEK 180S colourless | colorless | - 40118 2 | 20 l/PE can |
| 40119 | MEK 180S colourless | colorless | - 40119 9 | 5 l/sheet metal bucket |